GSM-021 ESIM-021 Auto dialer & text notification system Alarm and control system GSM 021 is used to inform a maximum of two users through the GSM network that an alarm has occurred. Users may also control one electrical device via their mobile phones, e.g. they may switch a lighting system on and off or open and close a gate.
GSM 021 may be connected to an intruder alarm control panel. It has two digital inputs (normally open), so that one detection device may be connected independently of the intruder alarm control panel, or alternatively two detection devices may be connected to GSM 021 without needing a control panel.
When a triggered zone is restored to pre-alarm, the system also sends an SMS or voice message confirming that this has been done.
Either user may turn the heating or lighting on or off, open gates, lift blinds etc. by sending GSM 021 a text message. Only one electrical device may be controlled in this way. The system remembers the status of output in the case of temporary electricity failures. The system will ignore requests and calls coming from unknown telephone numbers.
Application examples:
Object security option protects your home 24/7 and instantly informs you about unauthorized entry using SMS and voice call to your mobile phone. Information about water-supply accident (flood detection) minimizes damage to your personal assets and those of your neighbors in case of accidental water overflow from the water-supply system.
Electrical devices control by SMS (text message) – you can exercise remote control of an electric sauna, water pump, boiler, watering device; you can switch on or off lighting, heating and other electrically-controlled devices.
Sound channel option allows the user to hear what’s going on in the secured premises through their own mobile phone
Fire prevention - when the first smoke is detected, you are informed about it by SMS text message or voice call.
GSM 021 GSM dialer & Auto caller, used to inform users through GSM network that alarm has occurred where
user(s) can hear what's going on in the secured premises through own cell phone.
Simple installation and configuration - for quick system start it is enough only to enter user phone number. Just connect 3 wires (+12V, COM and Siren-Bell);
Technical specifications
- GSM modem frequency: 850/900/1800/1900 MHz
- Power Supply Voltage: 9-15V DC 300mA max
- Current used in standby mode: 30mA max
- Number of digital inputs (normal open): 2
- Allowable digital input voltage values: 0-30V
- Impulse duration: >600ms
- Number of Outputs: 1
- Output max parameters: 500mA; 30V
- Dimensions: 108x52x30mm
- Operating Temperature: -35...+55°C
|
|
|
GSM-021
|
|
|
This system offers allows quick upgrades to alarm
panels and other equipment to allow it to send texts and voice calls
when one of the inputs are triggered.
When one of the inputs are triggered, the unit will
send out text messages 'Alarm 1 Activated' or 'Alarm 2 Activated' and
follow these with a voice call to the pre programmed numbers.
Each input allows 6 seconds of voice recording.
Features:
- 2 inputs
- 1 Open collector output
- Text message alerts
- Audio monitoring (via optional microphone)
Technical Spec:
- GSM Modem Frequency: 900/1800/1900 MHz
- Power Supply Voltage: 10-24V AC/DC
- Inputs: 5
- Relay Output: 1
- Dimensions: 82x63x20mm
- Operating Temperature: -20...+55°C
|
|